PROCUREMENT SUPPORT APPLICATION

SAMPLE APPLICATION

MS1030-1

MAIN FEATURES

FEATURES

Flow Measurement Unit

● Measurement Accuracy of 15ps, 3.8ps at 1LSB

● Measurement Range from 500ns to 4ms @ 4MHz

● 8 Echo Signals can be Measured, Accumulated and Stored in the

Result Register 

● High-precision Pulse Width Detection Unit

Analog Input Circuit

● Built-in Stable Low-drift Precision Comparator, 

1mV (TYP) Offset Voltage 

● Built-in Programmable Comparator Bias Voltage,

-32mV~31mV Programming Voltage

● Built-in First-wave Detection Function with Programmable

Bias Voltage up to ±64mV

● Analog Section is Disabled during Non-measurement Time,

Power Dissipation less than 50nA

Pulse Generation Unit

● Built-in Two Pulse Generators, Generate up to 127 Pulse Singularly

● Pulse Generator Sends Pulse Frequency: 62.5kHz~2MHz @4MHz

● Pulse Generator Output 48mA Current Singularly

● Two Pulse Output Pins with a Single Reverse Function